How Central Laboratory Services Ensure Data Integrity Across Multi-Country Clinical Trials
In a multi-country trial that relies on local laboratories, the same blood test can be reported against a different reference range at each site. Where the protocol uses those ranges for eligibility or safety thresholds, the variation can affect which participants are enrolled and when dosing is interrupted. A global central laboratory service helps reduce this variation by standardising testing methods and reference ranges across study sites.
For sponsors managing multi-country clinical trials, a global central laboratory service supports consistency in testing, sample management and reporting across geographically dispersed study sites.
Selecting the right laboratory partner requires evaluating its technical capabilities, quality systems, and operational processes. Drawing on the three decades of experience operating a central laboratory, this blog outlines six key questions at the end of this article, that sponsors should consider when assessing a central laboratory service for clinical trial requirements.
One Sample, Several Reference Ranges
Investigators in a US research network studying fatty liver disease documented this variation while planning a paediatric trial. Across the 11 laboratories their centres used, the upper limit of normal (ULN) for ALT, a liver enzyme, ranged from 35 to 79 U/L for men. When all 11 analysed the same external quality-control sample, seven would have reported it as normal for a man and four as elevated. The measurements themselves were close, and the authors attributed most of the difference to the reference populations each laboratory had used to set its range.
The survey is small and dates from 2003 Protocols commonly express eligibility and stopping criteria as multiples of the ULN, such as interrupting dosing if ALT exceeds three times the ULN. With 11 different ULNs, the same ALT value could trigger a dose interruption at one site and not at another.
A central laboratory reports every result against one reference range, so 1.5 times the ULN carries the same meaning at a site in Nairobi as at a site in Pune. Over a multi-year study, a new batch of testing reagents can also shift results, so the laboratory compares each new batch with the current one on patient samples before use, following CLSI guideline EP26. Those records let a sponsor show that late-study results remain comparable with baseline.
Controlling Errors Before Testing
In a 2006 review of error studies, Mario Plebani reported that 46% to 68.2% of laboratory errors occurred before testing began, between sample collection and arrival at the laboratory. Those figures come from routine clinical laboratories; a multi-country trial adds courier transit and customs clearance to the same steps.
Some results change quickly after collection. Blood cells continue to consume glucose until the sample is centrifuged, and the 2023 ADA and AACC guideline reports an average decline of 5% to 7% per hour, varying with temperature and white cell count. At that rate, a sample left uncentrifuged for two hours would read roughly 10% to 14% low.
A central laboratory sets up controls for this phase before the first participant is screened:
- Visit kits with pre-labelled, barcoded tubes remove tube selection and handwritten labels from site workload.
- The laboratory manual sets time and temperature limits for processing and storing each sample type.
- Temperature loggers travel with each shipment, packed to international shipping rules for biological samples, so the laboratory can identify samples exposed to out-of-range temperatures.
- Chain-of-custody records document who handled each sample and when, as the European Medicines Agency (EMA) recommends in its 2012 reflection paper on trial laboratories.
DiagnoSearch's in-house central laboratory dedicated to clinical research uses a sample management system designed to track specimens from collection and transport through analysis, reporting and storage. Its global and domestic logistics support forms part of the operational framework for managing samples across geographically dispersed study sites.
Controls Within the Laboratory
Accreditation to ISO 15189 or by the College of American Pathologists (CAP) gives sponsors independent evidence of technical competence. Since December 2025, ILAC, the international accreditation network, has recognised only accreditations to the 2022 edition of ISO 15189. Trial work also brings good clinical practice (GCP) expectations that routine diagnostic testing does not.
For a clinical research laboratory, accreditation provides evidence of technical competence, but quality also depends on the processes used to validate and control testing. DiagnoSearch's central laboratory identifies robust validation and control processes as a core service capability, alongside its NABL accreditation to ISO 15189:2022 and College of American Pathologists (CAP) accreditation.
The EMA reflection paper recommends that a trial laboratory perform only the analyses set out in the protocol, contract, or work instructions, and document every repeat analysis against criteria agreed in advance. Without that control, an unrecorded re-test can obscure a failed result.
In 2011, the FDA notified sponsors that studies analysed at Cetero Research's Houston bioanalytical laboratory between 2005 and 2010 may need to be repeated or confirmed, after inspections found falsified records.
For the earliest studies, the FDA accepted two remedies:
- Re-analysis of stored samples where stability data supported it
- A repeat of the study.
A sponsor's options then depend on the laboratory's audit trail and on whether retained samples are still usable.
From the Laboratory to the Clinical Database
A result can be accurate in the laboratory information system and still be wrong in the clinical database. A unit mismatch is one example: glucose converts from mmol/L to mg/dL by a factor of about 18, and a transfer that omits the conversion shifts every glucose value in the dataset. ICH E6(R3) states that validated processes, or reconciliation, should be in place when data move between computerised systems.
The transfer of laboratory results into clinical data management systems is another point where operational coordination matters. DiagnoSearch offers customised result management, flagging and data transfer to clinical data management (CDM), supported by trial management reports. For sponsors, the relevant consideration is how these processes are defined for the study and how data completeness and discrepancies are managed across systems.
Laboratory results can also unblind a study. In a lipid-lowering trial, site staff who see a marked fall in LDL cholesterol can guess which arm a participant is in. Under section 4.1 of E6(R3), the potential for unblinding should form part of the trial's risk assessment, and a central laboratory can support this by withholding those results from site reports under an agreed blinding plan.
Where Local Laboratories Still Have a Role
Central testing has trade-offs. Transit takes hours to days, which can rule out samples that degrade quickly, and an investigator who needs a potassium result before dosing cannot wait for a courier.
The choice of testing approach also depends on the study's protocol, the required parameters and sample handling requirements. DiagnoSearch's central laboratory offers a test menu covering safety testing, efficacy parameters, immunology, serology, biomarkers and infectious diseases, with protocol-specific menu extensions where needed. Its biobanking facilities also support long-term specimen storage under ambient, refrigerated and frozen conditions.
Six Questions for Central Laboratory Selection
Ask the laboratory to answer these against your protocol and site list, with supporting documents rather than general assurances.
- 1. Which edition of ISO 15189 does your accreditation certificate cite? Expect the 2022 edition.Check that the trial's key tests fall within the accreditation scope.
- 2. Can every site get samples to you within each test's stability limit? Compare the stability data behind each shipping window with courier transit times from your most remote sites. A good answer identifies sites that need a different approach, such as local processing and frozen shipment.
- 3. How do you check a new batch of reagents before using it? A good answer describes a documented comparison of the current and new batches on patient samples, with acceptance criteria set in advance, in line with CLSI EP26. Ask to see the records from a study of similar duration.
- 4. What does your data transfer specification cover, and how often do you reconcile? A good answer covers test codes, units, reference ranges, and transfer frequency, with a fixed schedule for matching samples against EDC visits. For FDA submissions, results also need LOINC codes, which the FDA has required in marketing applications for studies starting after 15 March 2020.
- 5. Which results will you suppress to protect the blind? A good answer names the tests, the roles with access to them, and how the laboratory logs and reports an inadvertent release.
- 6. What did your last regulatory inspection or sponsor audit find? Ask for the findings and how and when each was closed. Detailed answers are more useful than a general statement of compliance.
Operating since 1996, DiagnoSearch‘s central laboratory service, supports Phase I-IV clinical trials for multinational and domestic sponsors across APAC, Europe, South America and Africa.
The laboratory holds NABL accreditation to ISO 15189:2022 since 2013 and CAP accreditation since 2005.
For sponsors planning a multi-country study, DiagnoSearch provides a central laboratory service for clinical trials, with capabilities spanning testing, sample logistics, biobanking and laboratory data transfer. The team can discuss the requirements and address questions with you against your protocol and site list.
References
- Neuschwander-Tetri BA, Ünalp A, Creer MH; Nonalcoholic Steatohepatitis Clinical Research Network. The upper limits of normal for serum ALT levels reported by clinical laboratories depend on local reference populations. Arch Intern Med. 2008;168(6):663–666. Available at: https://pmc.ncbi.nlm.nih.gov/articles/PMC3670191/
- International Council for Harmonisation. ICH E6(R3) Guideline for Good Clinical Practice. Step 4, 6 January 2025. EMA/CHMP/ICH/135/1995. Available at: https://www.ema.europa.eu/en/documents/scientific-guideline/ich-e6-r3-guideline-good-clinical-practice-gcp-step-5_en.pdf
- Clinical and Laboratory Standards Institute. EP26: User Evaluation of Acceptability of a Reagent Lot Change. 2nd ed. Wayne (PA): CLSI; 27 April 2022. Available at: https://clsi.org/standards/products/new-products/documents/ep26
- Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med. 2006;44(6):750–759. Available at: https://doi.org/10.1515/CCLM.2006.123
- Sacks DB, Arnold M, Bakris GL, et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care. 2023;46(10):e151–e199. Available at: https://pmc.ncbi.nlm.nih.gov/articles/PMC10516260/
- World Health Organization. Guidance on regulations for the transport of infectious substances 2025–2026: applicable as from 1 October 2025. Geneva: WHO; 2025. Available at: https://www.who.int/publications/i/item/9789240120822
- European Medicines Agency, GCP Inspectors Working Group. Reflection paper for laboratories that perform the analysis or evaluation of clinical trial samples. EMA/INS/GCP/532137/2010. Adopted 28 February 2012. Available at: https://ema.europa.eu/en/documents/regulatory-procedural-guideline/reflection-paper-laboratories-perform-analysis-or-evaluation-clinical-trial-samples_en.pdf
- International Laboratory Accreditation Cooperation. ISO 15189:2022 for medical labs published (ILAC Resolution GA 26.08). Available at: https://ilac.org/latest_ilac_news/iso-151892022-for-medical-labs-published/
- Reuters (via NBC News). FDA finds drug research firm faked samples, documents. 27 July 2011. Available at: https://www.nbcnews.com/news/amp/wbna43916257
- PharmaTimes. Cetero reaches FDA resolution on study re-runs. 2012. Available at: https://pharmatimes.com/?p=54372
- Food and Drug Administration. Extension of the timetable requirement to submit study data in Logical Observation Identifiers Names and Codes. Federal Register. 20 October 2017;82(202):48827–48828. Available at: https://regulations.justia.com/regulations/fedreg/2017/10/20/2017-22768.html
- DiagnoSearch Life Sciences. Central Laboratory. Available at: https://www.diagnosearch.com/central-laboratory.html
FAQ's
What is the role of a central laboratory in multi-country clinical trials?
A central laboratory helps standardise clinical testing across geographically dispersed study sites by using consistent analytical methods, reference ranges and reporting processes. This reduces inter-laboratory variability and supports the comparability of results across countries. A central Laboratory service for clinical trial programmes also coordinates sample logistics, testing and reporting to support consistent laboratory data throughout the study.
What types of tests are performed by a central laboratory in clinical trials?
Central laboratories support a range of clinical trial assessments, including haematology, clinical chemistry, safety testing, immunology, serology, infectious disease testing and biomarker analysis. The specific test menu depends on the study protocol, therapeutic area and required endpoints. Protocol-specific testing requirements can also be accommodated to support different phases of clinical development.
How are clinical trial samples tracked and protected during international transportation?
Clinical trial samples are managed through defined collection, processing, packaging and transportation procedures. Barcoded collection tubes, sample tracking systems, temperature monitoring and chain-of-custody records help maintain specimen traceability. A central laboratory also establishes sample stability requirements and shipping procedures to minimise the risk of degradation or compromised results during international transit.
How do central laboratory services support clinical trial data management?
Central laboratories generate standardised test results that must be accurately transferred into clinical data management systems. Defined data transfer specifications, unit conversions, validation checks and reconciliation processes help identify discrepancies and maintain data consistency. Coordination between laboratory teams and Clinical Data Management Services supports reliable datasets for statistical analysis and clinical study reporting.
Why is quality assurance important in clinical trial laboratory testing?
Quality assurance helps ensure that laboratory testing is performed using validated methods, documented procedures and appropriate quality controls. It supports the accuracy, reproducibility and traceability of laboratory results throughout a clinical trial. Clinical Quality Assurance Services also help identify process deviations and documentation gaps, strengthening confidence in the data generated for regulatory review.
Can local laboratories be used alongside a central laboratory in clinical trials?
Yes. A hybrid approach may be appropriate when certain tests require immediate results or when sample stability limits make international transportation impractical. Local laboratories can support time-sensitive assessments, while a central laboratory manages testing that benefits from standardised methods and consistent reporting across study sites. The approach should be defined according to the study protocol and operational requirements.
How do central laboratories support biomarker analysis in clinical research?
Central laboratories support biomarker assessments by applying consistent testing methods and quality controls across clinical trial samples. Biomarker data can help researchers evaluate biological responses, explore disease mechanisms and assess treatment effects. Depending on the study requirements, specialised analytical capabilities and validated assays may be needed to generate reliable biomarker data across participating sites.